In metal injection moulding, corrosion resistance is not a pure material property. It is the result of alloy, sintered density, surface condition and post-treatment. A MIM part in 316L with insufficient sintered density is less corrosion resistant than a wrought part in the same alloy, because open residual porosity offers attack area and promotes crevice corrosion.
That is why every figure on this page is accompanied by the process condition under which it applies.
Property data
All values are supplier data from datasheets declaring conformity with MPIF Standard 35 or ASTM B883, or normative minimum values where those are freely available. Where minimum and typical values differ, both are given.
| Material | Condition | Rm | Rp0.2 | A | Density | Hardness |
|---|---|---|---|---|---|---|
| MIM 316L | as-sintered, minimum | 450 MPa | 140 MPa | 40 % | — | — |
| MIM 316L | as-sintered, typical | 520 MPa | 175 MPa | 50 % | 7.6 g/cm³ | 67 HRB |
| MIM 304L | as-sintered, supplier range | 450 – 630 MPa | 160 – 180 MPa | 25 – 50 % | 7.5 – 7.75 g/cm³ | up to 100 HRB |
| MIM 17-4 PH | as-sintered, minimum | 790 MPa | 650 MPa | 4 % | — | 27 HRC |
| MIM 17-4 PH | as-sintered, typical | 900 MPa | 730 MPa | 6 % | 7.5 – 7.66 g/cm³ | 27 HRC |
| MIM Ti-6Al-4V | ASTM F2885 Type 2, as-sintered | 780 MPa | 680 MPa | 10 % | 4.20 g/cm³ | up to 30 HRC |
| MIM Ti-6Al-4V | ASTM F2885 Type 1, densified | 900 MPa | 830 MPa | 10 % | close to 4.43 g/cm³ | — |
| MIM CoCrMo | as-sintered, supplier data | 992 MPa | 551 MPa | 30 % | 8.3 g/cm³ | 25 HRC |
Young's modulus for the stainless grades is around 190 GPa. The spread on MIM 304L is real and not an imprecision of this presentation: supplier figures differ considerably because 304L is not listed in MPIF Standard 35. Anyone specifying 304L should fix the property values supplier by supplier.
Selection by application
| Requirement | First choice | Second choice | Note |
|---|---|---|---|
| Moisture, perspiration, skin contact | MIM 316L | MIM Ti-6Al-4V | 316L passivated, titanium resistant without post-treatment |
| Corrosion resistant and strong | MIM 17-4 PH | — | considerably stronger than 316L, but less resistant to chlorides |
| Surgical instruments | MIM 316L, MIM Ti-6Al-4V | MIM CoCrMo | implant suitability requires separate validation, see below |
| Chloride-bearing media | MIM 316L at elevated density | MIM Ti-6Al-4V | molybdenum content and residual porosity decide jointly here |
| Low weight with resistance | MIM Ti-6Al-4V | — | 4.2 g/cm³ against 7.6 g/cm³ for 316L |
The four points that decide the outcome
Sintered density and open porosity
Closed porosity inside the part matters little for corrosion. Open porosity connected to the surface matters a great deal: it acts as a crevice in which medium collects and the passive layer breaks down locally. In sintered materials the transition from open to closed porosity lies around 92 to 95 percent of theoretical density. That is the reason for the density requirement.
Passivation
MIM 316L is passivated like any other austenitic stainless steel. The difference lies in the preparation: residual binder and carbon from debinding must be removed, otherwise no uniform passive layer forms. Passivation therefore belongs in the process agreement, not in the assumption.
Carbon and oxygen content
For titanium this is the critical point. ASTM F2885 limits oxygen to 0.20 percent and carbon to 0.08 percent. Both are picked up during debinding and sintering if the process is not set up for it. Exceedances embrittle the part without showing immediately in tensile strength — elongation falls first. The analysis belongs in the first article report.
Surface roughness
EPMA gives roughly Ra 0.8 µm for the as-sintered condition. For applications with a cleaning requirement or skin contact that is usually sufficient; for sealing faces and instrument geometries the part is polished or electropolished. Electropolishing additionally improves corrosion resistance because it removes the deformed and contaminated surface layer and enriches the surface in chromium. It does, however, expose near-surface pores — at low sintered density the result can therefore be worse than before treatment.
What belongs in the specification
- Material with standard, not just a short name
- Condition: as-sintered, heat treated, densified
- Minimum density as a percentage of theoretical density or in g/cm³
- Surface condition: as-sintered, blasted, polished, passivated, electropolished
- For titanium, additionally the permissible oxygen and carbon contents
- Measurement method for density, usually Archimedes or metallographic section
Our approach
We specify density and surface condition alongside the alloy, because the material name alone does not carry the requirement. For applications with a corrosion requirement we supply density and passivation evidence as part of the first article inspection, regardless of which plant produces the part.
Further reading
- MIM 316L is not 1.4404 — why the comparison with the wrought material misleads.
- Titanium in MIM — oxygen pick-up and what it costs.
- Density, porosity and HIP — the link between density and resistance.